Fibre Channel Initiator Emulation
The SANBlaze SANBlazter Initiator Emulator is a unique Fibre Channel test
solution that provides simulation of a single to hundreds of Fibre Channel
Initiator ports. The software operates on existing SANBlaze VirtuaLUN
and GargantuLUN 4G Fibre Channel systems, and runs standalone or in conjunction
with SANBlaze Target Emulation software.
Available in 2, 4, 12 or 24 port 4G Fibre Channel systems, the SANBlazter
software behaves as a real initiator, not just a traffic generator or
protocol tester, providing real login and command control. Features such
as Read/Write/Compare testing, error injection and a custom command builder
provide an environment to simulate Initiator test cases via script or
an easy to use Web interface. The Patent Pending Blazter Mode allows for
all ports to run at full line rate.
New Podcast on SANBlaze Target Emulators Listen
Now
New SANBlaze Target Emulators and Initiators Solutions
Brochure
Hardware:
* Fibre Channel Ports: 2, 4, 12 or 24 Fibre Channel Ports running at 1,
2 or 4 Gbps
* Auto Link Speed and Auto Topology Negotiation
* One Initiator per port (Initial Release)
* Multiple Initiators per port (Virtual NPort) ( Spring 2007)
Software Features:
* Blazter Mode
o Full speed setting, allowing read/write testing to run at full 4G line
rates across all ports
* Command Builder - Build/send custom or predefined commands including:
o Test Unit Ready
o ModeSense
o ModeSelect
o ReportLuns
o Inquiry and Inquiry VPD
o ReadCapacity
o Read (6,10, 12,16)
o Write (6,10, 12,16)
o WriteSame
o Standard Reserve Operations (Reserve6, Release6)
o PersistentReserve Operations
o Variable Block Size (512 or 520 Byte)
* Configurable Initiator/HBA identity
o WWNN
o WWPN
* Data Testing
o Read/Write
o Read/Write/Compare
o IOMeter Integration
* Discovery Methods
o ReportLuns
o Scan LUN0
o Scan All LUNS
* Trace Mode
o A viewable, time-stamped log of all IO’s sent or received, including
errors
Error Capabilities:
* Customizable Error Handling:
o Retry on Error
o Stop on Error
o Adjustable IO timeouts
* Error Conditions:
o Bad CRC
o Read Over/Read Under
o WriteOver/Write Under
o Data Corruption
o LIP
o Offline/Online
o Logout
o Process Logout
* Task Management Commands
* Abort Task
* AbortTaskSet
* ClearTaskSet
* ClearACA
* LunReset
* TargetReset
Since 1997, Gillaspy Associates has built
a solid reputation for developing strong relationships with our customers
by providing quality solutions and ongoing support.
|
Emulation Home
Target Emulation
Initiator Emulation
Initiator Fibre Channel
Initiator SAS
System Platforms
SANBlaze
|